Advice

New build overheating: how to cool an apartment

Learn why new-build apartments overheat, how to manage glazing and ventilation, and when portable air conditioning can help without compromising safety.

Cool the apartment by controlling heat in and heat out

To cool a new-build apartment, reduce sunlight entering through the glass, limit indoor heat sources and ventilate when outside air is cooler. If those measures cannot keep the rooms you use comfortable, properly vented air conditioning can remove heat directly. Start by identifying how heat enters and why it cannot escape: simply opening every window may make things worse.

New build overheating is often a combination of large glazed areas, well-insulated construction and limited ventilation opportunities. Insulation slows heat transfer in both directions; it does not generate heat, but heat already inside can be slow to leave. Apartments with windows on only one side have fewer opportunities for cross-ventilation, especially where openings are restricted.

Put a thermometer in the main living space and another in the bedroom, away from direct sunlight, appliances and air outlets. Record readings in the morning, late afternoon and before bed for several days, alongside outdoor conditions and window use. A sharp afternoon rise suggests solar gain; warmth persisting overnight points towards inadequate heat removal or continuing internal heat sources.

Treat large windows as the first control point

Shade glazing before sunlight reaches the room, rather than waiting until the apartment feels hot. External shading is generally more effective because it intercepts sunlight before it passes through the glass. Where external changes are impractical, use suitable blinds or curtains and close them on the sunlit side while keeping other rooms usable.

Watch which windows receive direct sun and at what time. An apartment may need morning shading on one elevation and afternoon shading elsewhere; a single routine for every blind can miss the main heat gain. Large glazed doors can admit substantial sunshine even when the outdoor air feels relatively mild. Keep shading clear of ventilation openings.

Ask the managing agent before adding external blinds, balcony screens or window alterations. Do not attach makeshift shades where wind could dislodge them or where they obstruct drainage, access or ventilation. Check solar-control films with the glazing manufacturer or a competent installer: compatibility with the glass, thermal stress and warranty conditions matter. Dark film is not automatically a safe or effective solution.

Use windows according to temperature, not the clock

Open windows for cooling when outside air is cooler than the air indoors, provided conditions are safe. During hotter periods, reduce unnecessary window opening while preserving the background ventilation the apartment needs. Ventilation removes heat only when incoming air can carry it away; hot outdoor air can add to the problem.

Compare indoor readings with outdoor air measured in shade, not against a sun-warmed wall or balcony surface. Where safe, open windows on different elevations and internal doors to create a through-route. In a single-aspect apartment, airflow may remain weak even with the available windows open. Restricted openings can further limit how quickly warm air is replaced.

Do not defeat window restrictors, prop open communal fire doors or use a shared corridor as a ventilation route. Noise, security, rain and outdoor pollution may make overnight opening unsuitable. A fan can make an occupied space feel cooler by moving air over people, but it does not lower the room temperature and is not a substitute for removing accumulated heat.

Check what the ventilation system actually does

Mechanical ventilation is not necessarily air conditioning. Many new-build apartments have continuous extract ventilation or mechanical ventilation with heat recovery, usually called MVHR. These systems manage air exchange; their presence does not mean the building can actively cool itself. Identify the system from its controls, labels or handover documents before changing settings.

An MVHR summer bypass, where fitted, allows air to bypass heat recovery when the controls judge conditions suitable. It does not refrigerate the supply air. If outside air is warm, bypass operation cannot provide cold air, and normal ventilation airflow may be insufficient to remove strong solar gains. Use the manufacturer's instructions rather than assuming a particular switch position means cooling.

Check accessible filters and clean or replace them as instructed. Keep supply and extract terminals unobstructed, but do not rotate adjustable valves or alter balancing settings yourself. Report persistent faults, unusual noise or apparently weak airflow to the responsible maintenance team. Do not switch the whole system off to stop warmth: adequate ventilation remains necessary for moisture and indoor air quality.

Use air conditioning where heat cannot otherwise escape

Portable air conditioning is a practical option when shading and cooler-air ventilation are insufficient, but it needs a workable route for exhausting heat outdoors. Unlike a fan, it transfers heat out of the room. Choose the room that most needs cooling rather than assuming one portable unit will control an entire apartment through open doorways.

ChillDash hires professional-grade portable units rated at 12,000–14,000 BTU, delivered and collected nationwide. Suitability still depends on the room's floor area, ceiling height, glazing, sun exposure, occupancy and equipment heat. An open-plan kitchen and living room with extensive glass can be a more demanding load than a smaller enclosed room. Share these details when checking availability.

For a hose-exhaust unit, confirm that the supplied hose and a suitable window panel or seal fit your opening. Keep the hose within the manufacturer's permitted length and arrangement, with no crushing or improvised extensions. Discharging into a corridor, ceiling void or enclosed balcony merely relocates heat within the building rather than providing a proper outdoor outlet.

Prepare one cooling zone before the unit arrives

Check the outlet, power supply and floor space before arranging equipment. Measure the window opening and the route between it and the intended unit position. Photograph awkward glazing, restrictors and nearby sockets so the supplier can assess the setup. A tilt-and-turn window or narrow opening may need a different sealing arrangement from a conventional hinged window.

Clear a stable position with the ventilation clearances specified for the unit. Plan the cable route to avoid trip hazards, and follow the supplier's electrical instructions rather than relying on extension leads or multiway adaptors. Confirm how condensate is handled: some operating conditions require tank emptying or drainage. Protect flooring and establish who will check for water.

Once installed, shade the room and close unnecessary openings while retaining required ventilation. Start cooling before the room reaches its daily peak, then monitor temperature, noise and any fault or tank indicators. Keep cooking and other heat-producing activities outside the cooling zone where possible. If performance is poor, check the exhaust seal, hose and filters before simply lowering the thermostat.

Recognise the limits of temporary cooling

A portable unit may not be suitable where there is no approved exhaust route, insufficient space or no suitable electrical supply. Fixed glazing is a significant obstacle, not a reason to drill a wall without permission. Where a hose cannot be installed safely, discuss an alternative system or a different room with the supplier and building manager.

Many portable units use a single exhaust hose and draw replacement air into the room as they discharge air outside. That replacement air may be warm, reducing effective cooling. This also makes the interaction with an apartment's ventilation system relevant. Seek competent advice if there are open-flued combustion appliances or concerns about pressure differences; do not block ventilation openings to compensate.

Noise and airflow can also determine whether the arrangement works in practice. Ask about the proposed unit's operating characteristics if it will be used during sleep or calls. Avoid directing cold airflow continuously at one seat or bed. Evaporative coolers are not equivalent replacements: they add moisture to the air and can be poorly suited to an already humid, enclosed apartment.

Escalate persistent heat as a building issue

Persistent overheating deserves investigation, not just a bigger cooling unit. Send the landlord, managing agent or developer a concise record showing room temperatures, times, outdoor conditions, shading and ventilation settings. Include photographs of restricted openings or ventilation faults and explain which rooms remain unusably warm. This is more informative than a single photograph of a thermometer.

Ask for the ventilation operating instructions, relevant maintenance records and any available overheating assessment. Request checks where heat appears to come from communal heating pipework, service cupboards or unusually warm shared areas. Do not adjust communal valves or remove insulation yourself. A building-services professional can investigate whether unwanted heat gains, ventilation faults or design constraints need addressing.

Keep immediate comfort measures separate from longer-term remedies. Temporary cooling can make a room usable while faults are investigated, but it cannot correct unsuitable glazing, inadequate shading or persistent distribution-system heat. Permanent changes need coordinated advice on building permissions, electrical capacity, ventilation and maintenance. If heat is affecting someone's health, seek appropriate medical advice rather than relying on room cooling alone.

Common questions

Should I turn off my heated towel rail in summer?

If it has a user-accessible control, switch it off when unnecessary and check whether it follows a timer. Establish whether it is electric or part of a heating system first. Ask maintenance about uncontrolled warmth rather than adjusting unfamiliar valves.

Will a dehumidifier cool my apartment?

No. A standalone dehumidifier removes moisture but releases heat into the room. It may help with a diagnosed damp problem, but it is not a replacement for air conditioning. Investigate persistent humidity and ventilation problems separately.

Can I fit a ceiling fan in a rented new-build flat?

Check permission with the landlord before installation. The mounting must suit the ceiling structure, and electrical work needs a competent installer. Confirm blade clearances and controls. A ceiling fan improves comfort through air movement rather than removing heat.

How can I measure how much electricity cooling uses?

Use the unit's electrical input information and actual running time, or a suitably rated energy monitor approved for the appliance. A smart meter can show whole-home changes, but other appliances affect the reading. Cooling capacity in BTU is not electrical consumption.

Does a good EPC rating mean an apartment will stay cool?

No. An Energy Performance Certificate is not a guarantee of summer comfort. Glazing, shading, orientation, ventilation opportunities and internal heat gains need separate consideration. When viewing an apartment, ask specifically about summer conditions and how its cooling strategy works.

Need air conditioning?

WHEN YOU NEED IT. WE'RE THERE.

Portable air conditioning delivered to your home or business.

Or send a full enquiry