BTU per Square Metre Calculator: UK Room Sizing Guide
Learn how to estimate air conditioning BTU per square metre for UK rooms, adjust for heat sources and check whether a portable unit will suit your space.
Start with 350–500 BTU per square metre
Allow roughly 350–500 BTU per hour of cooling capacity per square metre as an initial estimate for a typical UK room. Multiply the floor area by that range to get a starting point, rather than a guaranteed equipment size. A 20 m² room, for example, gives an estimate of 7,000–10,000 BTU per hour.
Use the lower end for a shaded room with a normal ceiling height, limited equipment and few occupants. Move towards the upper end where there is strong sunshine, more glazing or several people working. Conservatories, busy kitchens and rooms with substantial equipment can fall outside this range and need a more detailed assessment.
Air conditioner labels usually shorten BTU per hour to BTU. For sizing purposes, this describes how quickly the unit can remove heat, not how much electricity it uses. A floor-area calculation is useful for narrowing your options, but it cannot account for every source of heat.
Calculate your floor area, then multiply
The simple calculation is room length × room width × 350–500. Measure length and width in metres to get the floor area in square metres. For an L-shaped room, divide it into rectangles, calculate each area separately and add them together.
A room measuring 5 metres by 4 metres has an area of 20 m². Multiplying 20 by 350 gives 7,000 BTU per hour; multiplying it by 500 gives 10,000 BTU per hour. A larger room measuring 6 metres by 5 metres has an area of 30 m², giving an initial range of 10,500–15,000 BTU per hour.
Measure the space you actually intend to cool. If doors remain open to a hallway or another room, that extra area adds demand and makes the result less reliable. Closing internal doors usually makes it easier to maintain a comfortable temperature in the occupied room.
Adjust for sunshine, ceiling height and equipment
Choose within the range according to the room’s heat load, and seek a separate assessment where conditions are demanding. Two rooms with identical floor areas can need different cooling capacities because their windows, roofs, occupancy and equipment differ.
Strong afternoon sunshine through large windows can add considerable heat. Top-floor rooms beneath a warm roof may also be harder to cool than shaded rooms on lower floors. Blinds or suitable shading can reduce solar gain, although they do not remove the need to size the air conditioner properly.
The starting range is most useful for ordinary domestic ceiling heights of roughly 2.4–2.7 metres. Higher ceilings mean more air volume and potentially more exposed building surface. Computers, printers, cooking appliances and groups of people also release heat. Avoid adding arbitrary percentages for every factor: a heavily glazed room or equipment-filled workspace needs more than a floor-area estimate.
Check where 12,000–14,000 BTU units fit
Using this rule of thumb, a 12,000 BTU unit corresponds to roughly 24–34 m², while a 14,000 BTU unit corresponds to roughly 28–40 m². These are arithmetic guides, not promised coverage areas. The smaller area in each range assumes the higher heat load of 500 BTU per square metre.
ChillDash hires out professional-grade portable air conditioning units in the 12,000–14,000 BTU range to homes and businesses across the UK, with delivery and collection. Share your room dimensions, ceiling height, window exposure and intended use when checking suitability and availability.
Do not assume one portable unit will cool several separate rooms just because their combined floor area fits the calculation. Walls and doorways restrict airflow. A larger or divided space may need multiple units, provided each has a suitable exhaust route and electrical supply.
Make the exhaust arrangement part of sizing
A correctly sized portable air conditioner still needs a suitable route to discharge hot air outdoors. Check this before choosing capacity. Most portable units use an exhaust hose, and its permitted length and positioning depend on the model.
Follow the manufacturer’s instructions, keep the hose as short and straight as permitted, and seal the opening around the outlet. Discharging into a corridor, loft or neighbouring room simply moves heat elsewhere indoors. An unnecessarily long or poorly positioned hose can reduce performance.
Single-hose portable units also expel room air, which can draw warmer replacement air into the building through gaps. This is one reason a nominal BTU rating does not translate into a fixed room coverage figure. Installation, shading and keeping unnecessary doors and windows closed all affect the result.
Use the estimate to check suitability, not promise a temperature
Treat your calculated BTU range as a starting point for choosing equipment, not a prediction of the temperature you will achieve. Outdoor conditions, the building’s stored heat and continuing heat gains all influence performance.
Before arranging hire, confirm the room dimensions, occupancy, main heat sources, exhaust opening and available power supply. Mention any noise concerns, particularly for bedrooms or meeting rooms. These details help establish whether a portable unit is appropriate or whether the space needs a different cooling arrangement.
Common questions
How many BTU do I need for a 25 m² room?
Using 350–500 BTU per square metre gives an initial estimate of 8,750–12,500 BTU per hour. Sunshine, ceiling height, occupancy and equipment determine whether that range is appropriate.
Does a 12,000 BTU air conditioner use 12,000 watts?
No. A 12,000 BTU-per-hour rating represents approximately 3.5 kW of cooling capacity, not electrical consumption. Check the model’s rated electrical input to understand its power requirement.
Can I use this calculation for a conservatory?
Not reliably on its own. Extensive glazing can create heat gains that exceed a simple floor-area allowance. Glazing, shading, roof construction and the exhaust arrangement need assessing before selecting a unit.
Will a bigger air conditioner always cool better?
No. Extra capacity cannot correct a poor exhaust setup or distribute air through closed doors. Substantial oversizing can also cause some units to cycle frequently, so match the equipment to the room and its heat load.